DEA 230/2
|
|
The
DEA 230/2 is a high-performance dielectric measurement system
designed for both laboratory dielectric analysis of polymers
and in-process cure monitoring of thermosets. It features
frequency sweeping from 0.001 Hz to 100 kHz for the characterization
of a wide range of polymers. The DEA 230/2 utilizes the full
range of Micromet's dielectric sensors including the patented
Low Conductivity Integrated Circuit Sensor (Chip sensor)
for highly accurate measurements of both loss factor and
permittivity and for measuring conductivity values as low
as 10-16 siemens/cm. Two dielectric sensors can be monitored
simultaneously.
Main applications
include research and development of resins, composites,
paints, coatings, oils, and lubricants.
Return
to Top
|
|
DEA
230/10 Dielectrometer
|
|
The DEA 230/10
is a ten channel, fully integrated dielectric measurement
system containing the same high quality electronics as our
System III Microdielectrometer that is widely used throughout
the world. The DEA 230/10 is compatible with all Netzsch
dielectric sensors except the Low Conductivity Integrated
Circuit Sensor. Each channel monitors both dielectric and
temperature data and frequency sweeping capability enables
the full cure profile to be obtained in a single experiment.
Sensors and controlling computer interface cables are plugged
directly into the rear of the 230/10 which makes this integrated
design ideal for factory floor use. Ten channels allow multiple
samples, multiple locations, multiple parts, or multiple
processes to be monitored.
Main applications include process development,
monitoring, and control of composites,
coatings, electronic materials, and more.
Return
to Top
|
| |
DEA
230/1 Cure Monitor
|
|
The DEA 230/1 is
a complete, low cost, portable, single channel dielectric
measurement system. When controlled through RS-232 communications,
the system will measure and calculate a full range of dielectric
parameters, including loss factor, permittivity, conductivity,
ion viscosity, and temperature. Standard Micromet Software
packages may be used to control the DEA 230/1 or software
may be supplied by the user. Alternatively, the system will
output 0-5 Volt signals proportional to AC resistance, capacitance,
and temperature. Available frequencies are 0.1, 1, 10, 100,
1000 and 10000 Hz.
Main applications include QA/QC, process
development, monitoring and control of
composites, paints, and coatings.
Return
to Top
|
| |
DEA
231/1 Cure Analyzer
|
|
The DEA 231/1 Cure
Analyzer is a low cost dielectric cure monitoring system
designed for applications where high measurement speed at
only a single sensor location is required. The DEA 231/1
can measure at frequencies of 10, 100, 1000, and 10000 Hz
at a maximum sampling rate of 55 milliseconds and can also
accept inputs from a thermocouple, pressure sensor, and LVDT.
The 231/1 communicates over the parallel port with a controlling
computer running the ICAM Software for Windows95/98/NT.
Main applications include QA/QC, research,
and process development, monitoring, and
control of fast curing thermosetting resin
systems such as SMC, BMC, other molding
compounds and UV curing materials.
Return
to Top
|
|